4-201 International residential code incorporated.​

There is hereby incorporated by reference the International Residential Building Code of One- and Two-Family Dwellings, 2024 Edition, including Appendices BA, BB and BF, prepared and published in book form by the International Code Council, Inc., 4051 West Flossmoor Road, Country Club Hills, Illinois 60478-5795, hereby referenced as IRC.

(Ord. 244; Ord. 307; Ord. 348; Code 2026)

4-202 Amendments and additions.​

The following sections of the IRC are amended as follows:

Amend Section 101.1 Title, of the IRC by replacing “[NAME OF JURISDICTION]” with “City of Lake Quivira, Kansas.”

Amend the IRC by omitting all of Section R101.2 Scope of the IRC, and amend by adding in lieu thereof a new Section R101.2 Scope, which reads:

R101.2 Scope. The provisions of this code shall apply to the construction, alteration, movement, enlargement, replacement, repair, equipment, use and occupancy, location, removal and demolition of detached one- and two-family dwellings and townhouses not more than three stories above grade plane in height with a separate means of egress and their accessory structures not more than three stories above grade plane in height.

Exception: The following shall be permitted to be constructed in accordance with this code and State regulations.

(1) Live/work units located in townhouses and complying with the requirements of Section 508.5 of the International Building Code and where provided with an automatic sprinkler system complying with Section P2904.

(2) Owner-occupied lodging houses with five or fewer guestrooms.

(3) A care facility with five or fewer persons receiving custodial care within a dwelling unit.

(4) A care facility with five or fewer persons receiving medical care within a dwelling unit.

(5) A day care facility for five or fewer persons of any age receiving care within a dwelling unit.

Amend by omitting Sections R103, R104, R105, R106, R107, R108, R109, R110, R111, R112, R113, and R114 of the IRC, in their entirety, and amend by adding a new Section R103, which reads:

R103 Administrative Provisions. The administrative provisions of the 2024 International Building Code, Chapter 1, in its entirety, and as modified by the Code of the City of Lake Quivira, Kansas, along with Sections R101 and R102 of the IRC, shall govern all matters within the scope of this code.

Amend by omitting Table R301.2(1) Climatic and Geographic Design Criteria, of the IRC, and amend by adding in lieu thereof a new Table R301.2(1) Climatic and Geographic Design Criteria, which reads:

TABLE R301.2 — CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA (2024 IRC)
GROUND SNOW LOADWIND DESIGNSEISMIC DESIGN CATEGORYSUBJECT TO DAMAGE FROMWinter Design TempICE BARRIER UNDERLAYMENT REQUIREDFLOOD HAZARDSAIR FREEZING INDEXMEAN ANNUAL TEMP
Speed (mph)Topographic effectsSpecial wind regionWindborne debris zoneWeatheringFrost line depthTermite
20115NoNoNoASevere36Moderate to Heavy6 Degrees FYesa)11/14/1978
b)8/3/2009
c)Panel #’s 20091C0001G Thru 20091C0007G And 20091C0016G Thru 20091C0022G And 20091C0030G Thru 20091C0037G
20115
For SI: 1 pound per square foot = 0.0479kN/m.0 squared, 1 mile per hour = 1.609km/h.

Amend the IRC by omitting all of Section R302.3 TWO-FAMILY DWELLINGS, of the IRC, and amend by adding in lieu thereof a new Section R302.3 TWO-FAMILY DWELLINGS, which reads:

R302.3 Two-family dwellings. Two-Family dwellings shall be separated from each other in accordance with Section R302.2 Townhouses.

Amend the IRC by adding a new Section R302.7.1 Under Stairway Protection, which reads:

R302.7.1 Under Stairway Protection. Under-stair surfaces of stairways shall be protected with ½-inch gypsum board.

EXCEPTIONS:

(1) Exterior stairways.

(2) Stairways of noncombustible materials.

(3) Decorative and open stairways where approved by the building official.

Amend the IRC by omitting all of Section R307 STORM SHELTERS, of the IRC, and amend by adding in lieu thereof a new Section R307 STORM PROTECTION AREAS, which reads:

SECTION R307 – STORM PROTECTION AREAS

R307.1 Storm protection area required. All new one- and two-family dwellings and townhouses shall contain a storm protection area meeting the standards set forth for group R occupancies in accordance with section 423.6 of the International Building Code as adopted and amended.

Amend the IRC by omitting all of Section R309 AUTOMATIC FIRE SPRINKLER SYSTEMS of the IRC, and amend by adding in lieu thereof a new Section R309 AUTOMATIC FIRE SPRINKLER SYSTEMS, which reads:

SECTION R309 - AUTOMATIC FIRE SPRINKLER SYSTEMS

R309.1 Townhouse automatic sprinkler systems. An automatic fire sprinkler system shall be installed in townhouses.

Exception: An automatic sprinkler system shall not be required where additions or alterations are made to existing townhouses that do not have an automatic sprinkler system installed.

R309.1.1 Design and Installation. Automatic sprinkler systems for townhouses shall be designed and installed in accordance with Section P2904 or NFPA 13D.

Amend the IRC by omitting all of Section R310.2.2 Alterations, Repairs and Additions, of the IRC, and amend by adding in lieu thereof a new Section R310.2.2 Alterations, Repairs and Additions, which reads:

R310.2.2 Alterations, Repairs and Additions. Where alterations, repairs or additions requiring a permit occur, the individual dwelling unit shall be equipped with smoke alarms and carbon monoxide alarms located as required for new dwellings.

EXCEPTIONS:

Work involving the exterior surfaces of dwellings, such as the replacement of roofing or siding, or the addition or replacement of windows or doors, or the addition of a porch or deck, are exempt from the requirements of this section.

Installation, alteration or repairs of plumbing, mechanical or electrical systems are exempt from the requirements of this section.

Amend the IRC by adding a new Section R310.8 Heat Detectors, which reads:

R310.8 Heat Detectors. Any integral or attached garage to the main house shall be provided with a single heat detector. Heat detectors shall be hard wired and interconnected with the household smoke alarm system, such that the activation of the heat detector will activate all of the audible alarms of the required household smoke alarm system. The required heat detector is not required to incorporate audible alarm notification nor is any audible notification device required in the garage. The heat detector shall be listed for the ambient environment and installed per the manufacturer’s installation instructions.

EXCEPTIONS:

(1) Heat detectors shall not be required with alterations, repairs or additions.

(2) Heat detectors shall not be required in detached garages.

Amend the IRC by omitting all of Section R328 SWIMMING POOLS, SPAS AND HOT TUBS of the IRC, and amend by adding in lieu thereof a new Section R328 SWIMMING POOLS, SPAS AND HOT TUBS, which reads:

SECTION R328 - SWIMMING POOLS, SPAS AND HOT TUBS

328.1 General. The provisions of this Chapter shall control the design and construction of swimming pools, spas and hot tubs installed in or on the lot of a one- or two-family dwelling.

328.2 Pools in Flood Hazard Areas. Pools that are located in flood hazard areas including above-ground pools, on-ground pools and in-ground pools that involve placement of fill, shall comply with Section 328.2.1 or 328.2.2.

EXCEPTIONS: Pools located in riverine flood hazard areas which are outside of designated floodways.

328.2.1 Pools Located in Designated Floodways. Where pools are located in designated floodways, documentation shall be submitted to the Building Official which demonstrates that the construction of the pool will not increase the design flood elevation at any point within the jurisdiction.

328.2.2 Pools Located Where Floodways Have Not Been Designated. Where pools are located where design flood elevations are specified but floodways have not been designated, the applicant shall provide a floodway analysis that demonstrates that the proposed pool will not increase the design flood elevation more than 1 foot (305 mm) at any point within the jurisdiction.

328.3 Definitions. For the purposes of these requirements, the terms used shall be defined as follows and as set forth in Chapter 2.

BARRIER. A fence, wall, building wall or combination thereof which completely surrounds the swimming pool and obstructs access to the swimming pool.

SWIMMING POOL, Hot Tubs and Spas. Any structure intended for swimming or recreational bathing that contains water more than 24 inches (610 mm) deep. This includes in-ground, above ground and on-ground swimming pools, hot tubs and spas.

328.4 In-Ground Pools. In-ground pools shall be designed and constructed in compliance with ANSI/NSPI-5.

328.5 Above-Ground and On-Ground Pools. Above-ground and on-ground pools shall be designed and constructed in compliance with ANSI/NSPI-4.

328.6 Permanently Installed Spas and Hot Tubs. Permanently installed spas and hot tubs shall be designed and constructed in compliance with ANSI/NSPI-3.

328.7 Portable Spas and Hot Tubs. Portable spas and hot tubs shall be designed and constructed in compliance with ANSI/NSPI-6.

328.8 Barrier Requirements. The provisions of this section shall apply to the design of barriers for restricting entry into areas having pools and spas. Outdoor pools and spas and indoor swimming pools and spas shall be surrounded by a barrier that complies with Sections 328.8.1 through 328.8.10. Where premanufactured spas or hot tubs are equipped with a lockable safety cover complying with ASTM F1346, the areas where those spas or hot tubs are located shall not be required to comply with Sections 328.8.1 through 328.8.10. Where swimming pools are equipped with a powered safety cover that complies with ASTM F1346 and surrounded by a 4-foot fence with latching gates that does not allow passage of a 5-inch sphere, the areas where those pools are located shall not be required to comply with Sections 328.8.1 through 328.8.10.

328.8.1 Barrier height and clearances. Barrier heights and clearances shall be in accordance with all of the following:

(1) The top of the barrier shall be not less than 48 inches (1219 mm) above grade where measured on the side of the barrier that faces away from the pool or spa.

(2) The vertical clearance between grade and the bottom of the barrier shall not exceed 2 inches (51 mm) for grade surfaces that are not solid, such as grass or gravel, where measured on the side of the barrier that faces away from the pool or spa.

(3) The vertical clearance between a surface below the barrier to a solid surface, such as concrete, and the bottom of the required barrier shall not exceed 4 inches (102 mm) where measured on the side of the required barrier that faces away from the pool or spa.

(4) Where the top of the pool or spa structure is above grade, the barrier shall be installed on grade or shall be mounted on top of the pool or spa structure. Where the barrier is mounted on the top of the pool or spa, the vertical clearance between the top of the pool or spa and the bottom of the barrier shall not exceed 4 inches (102 mm).

328.8.2 Openings. Openings in the barrier shall not allow passage of a 4-inch-diameter (102 mm) sphere.

328.8.3 Solid barrier surfaces. Solid barriers that do not have openings shall not contain indentations or protrusions that form handholds and footholds, except for normal construction tolerances and tooled masonry joints.

328.8.4 Closely spaced horizontal members. Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members is less than 45 inches (1143 mm), the horizontal members shall be located on the pool or spa side of the fence. Spacing between vertical members shall not exceed 1 3/4 inches (44 mm) in width. Where there are decorative cutouts within vertical members, spacing within the cutouts shall not exceed 1 3/4 inches (44 mm) in width.

328.8.5 Widely spaced horizontal members. Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members is 45 inches (1143 mm) or more, spacing between vertical members shall not exceed 4 inches (102 mm). Where there are decorative cutouts within vertical members, the interior width of the cutouts shall not exceed 1 3/4 inches (44 mm).

328.8.6 Chain link dimensions. The maximum opening formed by a chain link fence shall be not more than 1 3/4 inches (44 mm). Where the fence is provided with slats fastened at the top and bottom that reduce the openings, such openings shall be not greater than 1 3/4 inches (44 mm).

328.8.7 Diagonal members. Where the barrier is composed of diagonal members, the maximum opening formed by the diagonal members shall be not greater than 1 3/4 inches (44 mm). The angle of diagonal members shall be not greater than 45 degrees (0.79 rad) from vertical.

328.8.8 Doors and gates. Doors and gates in barriers shall comply with the requirements of Sections 328.8.8.1 through 328.8.8.2 and shall be equipped to accommodate a locking device. Pedestrian access doors and gates shall open outward away from the pool or spa, shall be self-closing and shall have a self-latching device. Doors and gates shall not swing over stairs

328.8.8.1 Utility or service doors and gates. Doors and gates not intended for pedestrian use, such as utility or service doors and gates, shall remain locked when not in use.

328.8.8.2 Latch release. For doors and gates in barriers, the door and gate latch release mechanisms shall be in accordance with the following:

(1) Where door and gate latch release mechanisms are accessed from the outside of the barrier and are not of the self-locking type, such mechanism shall be located above the finished floor or ground surface not less than 54 inches (1372 mm).

(2) Where door and gate latch release mechanisms are of the self- locking type such as where the lock is operated by means of a key, an electronic opener or the entry of a combination into an integral combination lock, the lock operation control and the latch release mechanism shall be located above the finished floor or ground surface at not greater than 54 inches (1372 mm).

(3) Where the only latch release mechanism of a self-latching device for a gate is located on the pool and spa side of the barrier, the release mechanism shall be located at a point that is at least 3 inches (76 mm) below the top of the gate.

328.8.9 Structure wall as a barrier. Where a wall of a dwelling or structure serves as part of the barrier and where doors, gates or windows provide direct access to the pool or spa through that wall, one of the following shall be required:

(1) Operable windows having a sill height of less than 48 inches (1219 mm) above the indoor finished floor, doors and gates shall have an alarm that produces an audible warning when the window, door or their screens are opened. The alarm shall be listed and labeled as a water hazard entrance alarm in accordance with UL 2017.

(2) A safety cover that is listed and labeled in accordance with ASTM F1346 is installed for the pools and spas.

(3) An approved means of protection, such as self-closing doors with self-latching devices, is provided. Such means of protection shall provide a degree of protection that is not less than the protection afforded by Item 1.

328.8.9 On-ground residential pool structure as a barrier. An on-ground residential pool wall structure or a barrier mounted on top of an on-ground residential pool wall structure shall serve as a barrier where all of the following conditions are present:

(1) Where only the pool wall serves as the barrier, the bottom of the wall is on grade, the top of the wall is not less than 48 inches (1219 mm) above grade for the entire perimeter of the pool, the wall complies with the requirements of Section 328.8.

(2) Where a barrier is mounted on top of the pool wall, the top of the barrier is not less than 48 inches (1219 mm) above grade for the entire perimeter of the pool, and the wall and the barrier on top of the wall comply with the requirements of Section 328.8.

(3) Ladders or steps used as means of access to the pool are capable of being secured, locked or removed to prevent access except where the ladder or steps are surrounded by a barrier that meets the requirements of Section 328.8.

(4) Barriers that are mounted on top of on-ground residential pool walls are installed in accordance with the pool manufacturer’s instructions.

328.8.10 Natural barriers. In the case where the pool or spa area abuts the edge of a lake or other natural body of water, public access is not permitted or allowed along the shoreline, and required barriers extend to and beyond the water’s edge not less than 18 inches (457 mm), a barrier is not required between the natural body of water shoreline and the pool or spa.

Amend the IRC by adding a new Section R328 PHYSICAL SECURITY, which reads:

SECTION R333 - PHYSICAL SECURITY

R333.1 Purpose. The purpose of this Section is to establish minimum standards that incorporate physical security to make dwelling units resistant to unlawful entry.

R333.1.1 Scope. The provisions of this Section shall apply to all new structures.

R333.2 Doors. Except for vehicular access doors, all exterior swinging doors of residential buildings and attached garages, including the doors leading from the garage area into the dwelling, shall comply with Sections R 328.2.1 through R333.4.4. For purposes of this Section, doors leading from the garage area into the dwelling shall be deemed to be exterior doors.

R333.2.1 Wood Doors. Where installed, exterior wood doors shall be of solid core construction such as high-density particleboard, solid wood, or wood block core with a minimum thickness of one and three-fourths inches (1 ¾”) at any point. Doors with panel inserts shall be solid wood. The panels shall be a minimum of one inch (1”) thick. The tapered portion of the panel that inserts into the groove of the door shall be a minimum of one-quarter inch (1/4”) thick. The groove shall be a dado groove or applied molding construction. The groove shall be a minimum of one-half inch (1/2”) in depth.

R333.2.2 Steel Doors. Where installed, exterior steel doors shall be a minimum thickness of twenty-four (24) gauge.

R333.2.3 Fiberglass Door. Fiberglass doors shall have a minimum skin thickness of one-sixteenth inch (1/16”) and have reinforcement material at the location of the deadbolt.

R333.2.4 Double Doors. Where installed, the inactive leaf of an exterior double door shall be provided with flush bolts having an engagement of not less than one inch into the head and threshold of the doorframe.

R333.2.5 Sliding Doors. Where installed, exterior sliding doors shall comply with all of the following requirements:

(1) Sliding door assemblies shall be installed to prevent the removal of the panels and the glazing form the exterior with the installation of shims or screws in the upper track.

(2) All sliding glass doors shall be equipped with a secondary locking device consisting of a metal pin or a surface mounted bolt assembly. Metal pins shall be installed at the intersection of the inner and outer panels of the inside door and shall not penetrate the frames exterior surface. The surface mounted bold assembly shall be installed at the base of the door.

R333.3 Door Frames. The exterior door frames shall be installed prior to a rough-in inspection. Door frames shall comply with Sections R333.3.1 through R333.3.3 for the type of assembly installed.

R333.3.1 Wood Frames. Wood door frames shall comply with all of the following requirements:

(1) All exterior door frames shall be set in frame openings constructed of double studding or equivalent construction, including garage doors, but excluding overhead doors. Door frames, including those with sidelights shall be reinforced in accordance with ASTM F476-84 Grade 40.

(2) In wood framing, horizontal blocking shall be placed between studs at the door lock height for three (3) stud spaces or equivalent bracing on each side of the door opening.

R333.3.2 Steel Frames. All exterior door frames shall be constructed of eighteen (18) gauge or heavier steel and reinforced at the hinges and strikes. All steel frames shall be anchored to the wall in accordance with manufacturer specifications. Supporting wall structures shall consist of double studding or framing of equivalent strength. Frames shall be installed to eliminate tolerances inside the rough opening.

R333.3.3 Door Jambs. Door jambs shall comply with all of the following requirements:

(1) Door jambs shall be installed with solid backing in a manner so no void exists between the strike side of the jamb and the frame opening for a vertical distance of twelve inches (12”) each side of the strike. Filler material shall consist of a solid wood block.

(2) Door stops on wooden jambs for in-swinging doors shall be of one-piece construction. Jambs for all doors shall be constructed or protected as to prevent violation of the strike.

333.4 Door Hardware. Exterior door hardware shall comply with Sections R328.4.1 through R328.4.6.

R333.4.1 Hinges. Hinges for exterior swing doors shall comply with the following:

(1) At least two (2) screws, three inches (3”) in length, penetrating at least one inch (1”) into wall structure shall be used. Solid wood fillers or shims shall be used to eliminate any space between the wall structure and door frame behind each hinge.

(2) Hinges for out-swinging doors shall be equipped with mechanical interlock to preclude the removal of the door from the exterior.

R333.4.2 Strike Plates. Exterior door strike plates shall be a minimum of eighteen (18) gauge metal with four (4) offset screw holes. Strike plates shall be attached to wood with not less than three-inch (3”) screws, which shall have a minimum of one inch (1”) penetration into the nearest stud. Note: For side lighted units, refer to Section R328.4.6.

R333.4.3 Locks. Exterior doors shall be provided with a locking device complying with one of the following:

Single Cylinder Deadbolt shall have a minimum projection of one inch (1”). The deadbolt shall penetrate at least three-fourths inch (3/4”) into the strike receiving the projected bolt. The cylinder shall have a twist resistant, tapered hardened steel cylinder guard. The cylinder shall have a minimum of five (5) pin tumblers, shall be connected to the inner portion of the lock by solid metal connecting screws at least one-fourth inch (1/4”) in diameter and two and one-fourth inches (2 ¼”) in length. Bolt assembly (bolt housing) unit shall be of single piece construction. All deadbolts shall meet ANSI Grade 2 or Grade 3 specifications.

R333.4.4 Entry Vision and Glazing. All main or front entry doors to dwelling units shall be arranged so that the occupant has a view of the area immediately outside the door without opening the door. The view may be provided by a door viewer having a field of view of not less than one-hundred eighty (180) degrees through windows or through view ports.

R333.4.5 Side Lighted Entry Doors. Side light door units shall have framing of double stud construction or equivalent construction complying with Section R333.3.1, R333.3.2 and R333.3.3. The door frame that separates the door opening from the side light, whether on the latch side or the hinge side, shall be double stud construction or equivalent construction complying with Sections R333.3.1 and R333.3.2. Double stud construction or construction of equivalent strength shall exist between the glazing unit of the side light and wall structure of the dwelling.

R333.5 Street Numbers. Street numbers shall comply with Section R308.

R333.6 Exterior Lighting. Exterior lighting shall comply with Sections R333.6.1 through R333.6.2.

R333.6.1 Front and Street Side Exterior Lighting. All front and street side door entrances should be protected with a minimum of one light outlet having a minimum of sixty (60) watts of lighting (or energy efficient equivalent) installed so that the light source is not readily accessible.

R333.6.2 Rear Exterior Lighting. Homes with windows or doors near ground level below eight feet (8’) on the rear side of the house shall be equipped with a minimum of one light outlet having one-hundred (100) watt lighting (or energy efficient equivalent) and shall be of the flood light type. Those fixtures placed below eight feet (8’) shall be fixtures manufactured such that the light source is not readily accessible.

R333.7 Alternate Materials and Methods of Construction. The provisions of this Section are not intended to prevent the use of any material or method of construction not specifically prescribed by this Section, provided any such alternate has been approved by the enforcing authority, nor is it the intention of this Section to exclude any sound method of structural design or analysis not specifically provided for in this Section. The materials, methods or construction and structural design limitations provided for in this Section shall be used, unless the enforcing authority grants exception.

The enforcing authority is authorized to approve any such alternate provided they find the proposed design, materials, and methods of work to be at least equivalent to those prescribed in this Section in quality, strength, effectiveness, burglary resistance, durability, and safety.

Amend the IRC by adding a new Section R334 FENCE MATERIALS, which reads:

SECTION R334 - FENCE MATERIALS

R334.1 Materials. All fences, regardless of whether or not a permit is required for their construction, that are constructed, repaired, expanded, or enlarged after the effective date of this ordinance, shall be constructed only of approved fence materials. Approved fence materials shall mean materials normally manufactured for, used as, and recognized as, fencing materials such as: wrought iron or other decorative metals suitable for the construction of fences, masonry, concrete, stone, chain link, metal tubing, wood planks, and vinyl or fiberglass composite manufactured specifically as fencing materials that are approved by the Community Development Director or his/her designee. Approved fence materials shall be approved for exterior use and shall be weather and decay-resistant. The Community Development Director or his/her designee is authorized to evaluate proposed fence materials, and to determine if the proposed material is satisfactory and complies with the intent of the provisions of this code, and that the material is, for the purposed intended, at least the equivalent of that prescribed in this Chapter in quality, strength, effectiveness, durability and safety.

R334.2 Temporary Fencing. The Building Official is authorized to approve temporary fencing, such as plastic silt fence and safety fencing, for active construction projects. Temporary fencing shall not remain in place longer than is necessary to perform its function.

Amend by omitting Section R402.1 Wood Foundations of the IRC, and amend by adding in lieu thereof a new Section R402.1 Wood Foundations., which reads:

R402.1 Wood Foundations. Wood foundation systems are not allowed. All other references in this code to wood foundations systems are null and void.

Amend the IRC by adding a new Section R403.1.1.1 Continuous Footing Reinforcement, which reads:

R403.1.1.1 Continuous Footing Reinforcement. Continuous footing for basement foundation walls shall have minimum reinforcement consisting of not less than two (2) No. 4 bars, uniformly spaced, located a minimum 3 inches (3”) clear from the bottom of the footing.

Amend the IRC by adding a new Section R403.1.1.2 Column Pads., which reads:

R403.1.1.2 Column Pads. Column pads shall be a minimum of twenty-four inches (24”) and eight inches (8”) deep (24”x24”x8”). Reinforcement shall consist of a minimum of three (3) No. 4 bars each way, uniformly spaced. Deck column pads shall be a minimum of twelve inches (12”) in diameter and six inches (6”) in thickness and shall extend below the frost line specified in Table R301.2(1), unless specifically approved otherwise by the Building Official.

Amend by omitting Section R404.1.1 Design Required., of the IRC, and amend by adding in lieu thereof a new Section R404.1.1 Design Required., which reads:

R404.1.1 Design Required. A design in accordance with accepted engineering practice shall be provided for concrete or masonry foundation walls, including top of wall restraint details, when any of the conditions 1 through 10 listed below exist. A design in accordance with accepted engineering practice shall be provided for concrete slabs when conditions number eleven (11) exists. Where applicable, a standard design approved by the City may be used in lieu of a design from the design professional. For new single-family dwellings where standard designs approved by the City are used, the design professional sealing the plans shall specify the use of those designs on the approved plans or through a separate report.

(1) Walls are subject to hydrostatic pressure from ground water.

(2) Walls supporting more than 48 inches (48”) of unbalanced backfill that do not have permanent lateral supports at the top and bottom.

(3) Sites containing CH, MH, OL or OH soils as identified in Table R405.1.

(4) Foundation walls exceeding nine feet (9’) in height, measured from the top of the wall to the bottom of the slab.

(5) Lots identified on the subdivision grading plan as having more than six feet (6’) of fill or having a finished slope steeper than 4 horizontal to 1 vertical before grading.

(6) Footings and foundations with existing fill soils below the footing level.

(7) Sloping lots steeper than 4 to 1 before grading.

(8) Lots where some footings will bear on soil and others will bear on rock.

(9) Areas where problems have historically occurred.

(10) Stepped footing and foundation walls.

(11) Concrete floor slabs supported on more than twenty-four inches (24”) of clean sand or gravel fill or eight inches (8”) of earth fill.

Amend by omitting Section N1101.13 (R401.2) Application., of the IRC, and amend by adding in lieu thereof a new Section N1101.13 (R401.2) Application., which reads:

N1101.13 (R401.2) Application. Residential Buildings shall comply with section N1101.13.1, N1101.13.2, N1101.13.3 or N1101.13.4

Exception: Additions, alterations, repairs and changes of occupancy the existing buildings comply with Section N1109.

N1101.13.1 (R401.2.1) Prescriptive Compliance Option. The Prescriptive Compliance Option requires compliance with sections N1101 through N1104 and Section N1108.

N1101.13.2 (R401.2.2) Simulated Building Performance Option. The Simulated Building Performance Option requires compliance with section N1105.

N1101.13.3 (R401.2.3) Energy Rating Index Option. The Energy Rating Index (ERI) Option requires compliance with Section N1106.

N1101.13.4 (R401.2.4) Home Energy Rating System (HERS) Index. The HERS Index requires compliance with Section N1107.

Amend by omitting Section N1107 (R407) TROPICAL CLIMATE REGION COMPLIANCE PATH., of the IRC, and amend by adding in lieu thereof a new Section N1107 (R407) HOME ENERGY RATING SYSTEM (HERS) Index Compliance Path., which reads:

SECTION N1107 (R407) – HOME ENERGY RATING SYSTEM (HERS) Index Compliance Path

N1107.1 (R407.1) HERS Compliance. The HERS Index Compliance Path option shall comply with section N1107.1.1 (R407.1.1), table N1107.1.1 (R407.1.1) and Table N1107.1.2 (R407.1.2).

N1107.1.1 (R407.1.1) HERS Index. The HERS Index Compliance Path option is met by hiring a HERS rater and constructing a residence that scores 70 or less on the HERS index. A Preliminary HERS Certificate with ‘Draft’ watermark or a copy of a REM/Rate compliance report with ‘Draft’ watermark must be submitted with building permit plans. The ‘Draft’ HERS certificate or report shall identify the project address and include the HERS raters name and contact information.

All HERS ratings shall be performed by a rater accredited by the Residential Energy Services Network (RESNET). The HERS rater is required to perform a blower door test, duct blaster test, pre-drywall inspection and final inspection as part of the standard HERS Index rating process. The final HERS Index score must be posted on the Certificate required by Section N1101.14 (R401.3). The final HERS Certificate which indicates that the dwelling unit achieved a compliant HERS Index score must be submitted to the City before issuance of a Certificate of Occupancy. The final HERS certificate shall identify the project address and include the HERS raters name and contact information.

Table N1107.1.1 (R407.1.1) REQUIRMENTS FOR HERS INDEX
SECTIONTITLE
General
N1101.14Certificate
Building Thermal Envelope
N1102.1.1Vapor Retarder
N1102.2.4Eave Baffle
N1102.2.5.1Access hatches and door insulation installation and retention
N1102.2.10Slab-on-grade floors
N1102.2.11Crawl space walls
N1102.5.1.2Air leakage testing
N1102.5.1.3 #2Maximum air leakage rate
N1102.5.2Fireplaces
N1102.5.3Fenestration air leakage
N1102.5.4Recessed lighting
N1102.5.5Air-sealed electrical and communication outlet boxes
Table N1107.1.2Building Thermal Envelope
Mechanical
N1103.1Controls
N1103.3.6Duct Sealing
N1103.6Mechanical Ventilation.
TABLE N1107.1.2 (R407.1.2) BUILDING THERMAL ENVELOPE
Climate
zone
Fenestration
U-factor b
Skylight b
U-factor
Glazed
Fenestration
SHGC b
Ceiling
R-value
Wood
Frame
Wall
R-value
Mass
Wall
R-Value e
Floor
R-Value
Basement
Wall
R-value c
Slab d
R-Value
&
Depth
Crawl
Space c
Wall
R-Value
40.320.550.4049138/131910 / 13NR10/13

a. R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the installed R-value of the insulation shall not be less that the R-value specified in the table.

b. The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration.

c. “10/13” means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement walls.

d. NR shall mean no requirement.

e. The second R-value applies when more than half the insulation is on the interior of the mass wall.

Amend by omitting Section N1109 (R501) EXISTING BUILDINGS – GENERAL, Section N1110 (R502) ADDITIONS, Section N1111 (R503) – ALTERATIONS and Section N1112 (R504) - REPAIRS., of the IRC, and amend by adding in lieu thereof a new Section N1109 (R501) EXISTING BUILDINGS - GENERAL., which reads:

SECTION N1109 (R501) – EXISTING BUILDINGS – GENERAL

N1109.1 (R501.1) Scope. The provisions of Sections N1109 shall control the alteration, repair, addition and change of occupancy of existing buildings and structures.

N1109.1.1 (R501.1.1) General. Except as specified in this chapter, this code shall not be used to require the removal, alteration or abandonment of, nor prevent the continued use and maintenance of, an existing building or building system lawfully in existence at the time of adoption of this code. Unaltered portions of the existing building or building supply system shall not be required to comply with this code.

N1109.2 (R501.2) Compliance. Additions, alterations, repairs or changes of occupancy to, or relocation of, an existing building, building system or portion thereof shall comply with Table N1107.1.2 (R407.1.2).

Amend by omitting Section P2503.2 Concealment., of the IRC, and amend by adding in lieu thereof a new Section P2503.2 Concealment., which reads:

P2503.2 Concealment. A plumbing or drainage system, or part thereof, shall not be covered, concealed or put into use until it has been tested by the permittee, or his or her authorized representative. The Building Official may require that any test of the plumbing or drainage system be witnessed by the Building Official or his authorized representative.

Amend by omitting Section P2603.5.1 Sewer Depth of the IRC, and amend by adding in lieu thereof a new Section P2603.5.1 Sewer Depth, which reads:

P2603.5.1 Sewer Depth. Building sewers shall be installed as required by the appropriate authority having jurisdiction.

Amend by omitting Section E3901.4.3 Receptacle outlet location., of the IRC, and amend by adding in lieu thereof a new Section E3901.4.3 Receptacle outlet location, which reads:

E3901.4.3 Receptacle outlet location. Receptacle outlets rendered not readily accessible by appliances fastened in place, appliance garages, sinks, or range tops as covered in the exception to Section E3901.4.1, or appliances occupying assigned spaces shall not be considered as these required outlets. Required receptacle outlets shall be located in one or more of the following:

(1) On or above, but not more than 20 inches (508 mm) above, the countertop or work surface.

(2) Receptacle outlet assemblies listed for the use in countertops or work surfaces shall be permitted to be installed in countertops or work surfaces.

(3) Not more than 12 inches (305 mm) below the countertop or work surface. Receptacles installed below a countertop or work surface shall not be located where the countertop or work surface extends more than 6 inches (152 mm) beyond its support base. [210.52(C)(3)]

Amend by omitting “This exception shall expire September 1, 2026” of section E3902.14 Exception 3.

Amend by omitting Section E3902.18 Receptacles not required to be GFCI protected., of the IRC, and amend by adding in lieu thereof a new Section E3902.18 Receptacles not required to be GFCI protected., which reads:

E3902.18 Receptacles not required to be GFCI protected. The following receptacles shall not be required to be ground-fault circuit-interrupter protected:

(1) Receptacles that are not readily accessible and are supplied by a branch circuit dedicated to electric snow-melting, deicing, or pipeline and vessel heating equipment where such equipment is protected as required by NFPA 70. [210.8(A) Exception No. 1]

(2) A receptacle supplying only a permanently installed premises security system. [210.8(A) Exception No. 2]

(3) Listed weight-supporting ceiling receptacles (WSCR) utilized in combination with compatible weight-supporting attachment fittings (WSAF) installed for the purpose of supporting a ceiling luminaire or ceiling-suspended fan shall be permitted to omit ground-fault circuit-interrupter protection. If a general-purpose convenience receptacle is integral to the ceiling luminaire or ceiling-suspended fan, GFCI protection shall be provided. [210.8(A) Exception No. 3]

(4) Factory-installed receptacles that are not readily accessible and are mounted internally to bathroom exhaust fan assemblies shall not require GFCI protection unless required by the installation instructions or listing. [210.8(A) Exception No. 4]

(5) A dedicated single receptacle for a garage door opener, refrigerator, freezer, or a sump pump.

(Ord. 244; Ord. 307; Ord. 348; Code 2026)

4-203 Presumptions.​

For purposes of this article and the enforcement of the provisions thereof, there shall be a prima facie presumption that the owner of the real property shall be that Person reflected on the most recent evidence of ownership for the real property filed of record with the County wherein such real property is situated. The prima facie presumption of ownership shall be effective upon affidavit of an authorized agent or employee of the County wherein such property is located, attesting that deed or deeds attached thereto are a true and accurate copy of the official record, and are the most recent evidence of ownership for the described real property.

For purposes of this article and the enforcement of the provisions thereof, there shall be a prima facie presumption that the Person who owns or controls property on which a violation occurs, has caused or permitted such violation.

(Ord. 244; Ord. 307; Ord. 348; Code 2026)

4-204 Copies on file.​

There shall be at least one (1) copy of the code adopted by reference herein kept on file in the office of the City Clerk, to which shall be attached a copy of the incorporating ordinance, and which shall be marked or stamped, “Official Copy as Incorporated by Ordinance No. 348” with all sections or portions thereof intended to be omitted clearly marked to show any such deletion or change, and filed with the City Clerk and open to inspection and available to the public at all reasonable hours. The Municipal Judge and all administrative departments of the City charged with the enforcement of this Section shall be supplied, at the cost of the City, such number of official copies of such standard code similarly marked, deleted and changed as may be deemed expedient.

(Ord. 244; Ord. 307; Ord. 348; Code 2026)

4-205 Penalty.​

Any person or entity violating any provisions of this article shall, upon conviction, be punished by a fine of not less than fifty dollars and no more than two thousand five hundred dollars. Each day that any violation occurs or continues shall constitute a separate offense. The imposition of a penalty for any violation or noncompliance shall not excuse any violation, permit a violation to continue, or excuse any obligation to remedy any violation. The imposition of a penalty shall not prohibit any action to enforce compliance, prevent a violation, or remedy a violation, nor shall it prohibit the imposition of liens or assessments necessary to remedy a violation.

(Ord. 244; Ord. 307; Ord. 348; Code 2026)